home *** CD-ROM | disk | FTP | other *** search
- TITLE: 941205 GENERAL PROBLEMS ON INSTALLATION OF WARP, MAINTENANCE
- DESKTOP OR BEFORE THE FINAL REBOOT
-
- DESCRIPTION OF SYMPTOMS:
-
- 1. Customer receives sys3175 in os2mm.dll (PJ16290) on first
- reboot or Maintenance Desktop.
- 2. Customer receives sys3175 in unpack2.exe, when continuing
- installation through the maintenance desktop on any diskette.
- 3. OS2 is unable to operate your hard disk or your diskette drive.
- 4. System hangs on maintenance desktop.
- 5. System beeps on diskette #7 when asking for the diskette.
-
-
- RESOLUTION:
-
- Remark out the basedev=xxxxxxx.add from config.sys on the harddrive
- except ibmint13.i13 and ibm%flpy.add and the cdrom
- controller device driver (Where xxxxxx can be any character and % is
- replaced by 2 for microchannel system and a 1 if any other system).
- Also refer customer for possible 174 in Users Guide to OS/2 book
- additional explanation and actions.
- If customer has Ethernet Card (NE2000 Compatible), ask to
- customer to remove it (PJ15955).
-